Pitfalls in eye testing of children

Pitfalls in eye testing of children Inadequate testing environment: Testing in a room with poor lighting or distractions can lead to inaccurate results. Incorrect testing distance: Failing to maintain the appropriate testing distance can distort results and lead to false positives or negatives. Incorrect choice of eye chart: Using a chart that is not age-appropriate…

Logmar explained

What Are the Advantages of Switching to Using the Logarithmic Scale as a Measurement Unit in Vision Tests? A LogMAR Eye Chart (Logarithmic Minimum Angle of Resolution) is designed to enable a more accurate measurement of visual acuity than other methods. If vision test results are to be consistent and comparable, health authorities recommend the…

Practice vision charts

Here you can view, download, and print practice charts for children, and we recommend showing them to the child/test subject before the actual test on the vision chart. We have created practice charts for the 3 types of Optotypes: Eyekey, Similar, and Wekey. Eyekey Eyekey Download PDF – versions   Eyekey-swedish Eyekey-spanish Eyekey-norwegian Eyekey-italian Eyekey-german…

Optotypes for Children – A Science of Its Own

Optotypes for Children – A Science of Its Own Eye Charts for Children Often Have Serious Flaws An Unregulated Market The market for children’s eye charts is largely unregulated, leading to inaccurate and overly favorable vision test results for children, which can result in missed referrals and lack of treatment. Unfortunately, it is entirely up…

ISHIHARA visual color eye test

Color Vision Test with the ISHIHARA System The 38 ISHIHARA Plates Download the overview: Danish version PDF International version PDF   Plate 1 Everyone should be able to see the number 12. Plate 2 Normal vision: 8 Red-green deficiency: 3 Plate 3 Normal vision: 6 Red-green deficiency: 5 Plate 4 Normal vision: 29 Red-green deficiency:…

Lack of standards for eye charts for children

Lack of Standards for the Size of Figures Compared to Letters – leads to inconsistency across different vision tests and manufacturers. It is an obvious task for ophthalmological organizations and research institutions to examine widespread symbol optotypes and measure credible compensation factors. By following a more calibrated and standardized approach, it can be ensured that…

Manglende standarder for vægtning af børnetavler

Manglende standarder for størrelsen af figurer i forhold til bogstaver – fører til inkonsistens på tværs af forskellige synsprøver og producenter. Det er en oplagt opgave for oftalmologiske organisationer og forskningsinstitutioner at undersøge udbredte symboloptotyper og udmåle troværdige kompensationsfaktorer. Ved at følge en mere kalibreret og standardiseret tilgang kan man sikre, at synsprøver med symboler…

ISHIHARA farvesynstest

Farvesynstest med ISHIHARA systemet De 38 ISHIHARA plader Download oversigten: Dansk version PDF International version PDF     Plade 1 Alle bør kunne se nummer 12.   Plade 2 Normal visning: 8 Rød-grøn problem: 3   Plade 3 Normal visning: 6 Rød-grøn problem: 5   Plade 4 Normal visning: 29 Rød- grøn problem: 70 Plade…

Hvad er der galt med den gamle lyskasse?

Hvad er der galt med “den gode gamle synstavle”? “Hvorfor alt det postyr? Det er jo bare en screening!” “Ja, og netop den screening afgør om mulige synsproblemer afdækkes og visiteres til behandling i tide.” 10 grunde til at vi må se på synstavler med nye øjne: STANDARDER FØLGES IKKE – Desværre lever mange eksisterende…

Historien om udviklingen af den moderne synstest

Historien om udviklingen af den moderne synstavle Synsskarphedsrelaterede skalaer for visuel funktion Måling af synsstyrke starter med at definere stimulusparametrene: symbolstørrelse og synsafstand. Referencestandarden for størrelse blev defineret af Snellen; navnet »M-enhed« blev opfundet af Sloan. Referencestandarden for afstand er meteren og dens omvendte, dioptrien. På baggrund af disse parametre kan vi beskrive, hvordan øjet…

Faldgruber i synstest af børn

Faldgruber i synstest af børn Utilstrækkelig testmiljø: Testning i et rum med dårlig belysning eller forstyrrelser kan føre til unøjagtige resultater. Forkert testafstand: Manglende vedligeholdelse af den passende testafstand kan forvrænge resultaterne og føre til falske positive eller negative resultater. Forket valg af synstavle: der ikke er alderspassende, eller brug af diagrammer med ukendte symboler…

Måleenheder

Måleenheder Synsskarphed øges ikke lineært! – men derimod logaritmisk –  i forhold til størrelsen af de visuelle elementer. Når synsskarphed testes, bruges logaritmisk skala til at graduere størrelsen af bogstaverne eller symbolerne på tavlen, så de bliver mindre og mindre i en logaritmisk progression. Den logaritmiske skala gør det muligt at evaluere synsskarpheden på en…

Crowding og horror vacuum

Crowding Verden er kompleks og vores syn skal skelne mange ting fra hnianden,  også når de er mange og står tæt. Synstavler udformes med crowding-effekten i tankerne af flere grunde, der alle sigter mod at sikre nøjagtige og pålidelige synsskarphedsmålinger samt at forbedre den diagnostiske proces: Repræsentativt for virkelige situationer: I virkeligheden oplever folk ofte…

Placering af synstavlen

Placer synstavlen korrekt for at få nøjagtige synstestresultater Hvis alle synstavler var kalibreret ens og havde samme mål, og vi mennesker alle var lige høje, kunne en synstavle altid placeres i samme højde og afstand fra testpersonen, barn eller voksen, og vi kunne være sikre på altid at få et sandt synstestresultat. Da ingen af…